Admin Request for Inspection REA Solar Mini Grid
| Application for | REA Solar Mini-Grid Project |
|---|---|
| REA Code | REA-NEP-MG |
| REA LOT Number | Null |
| REA-NEP-MG | PBG |
| Register as | Corporate |
| NEMSA Certificate Number | RECC/CEIF/PR/00254 |
| First Name | ZHENGQUAN |
| Last Name | ZHOU |
| Other Name | JOEY |
| Position | MANAGING DIRECTOR |
| Phone | 08037259175 |
| zhouzq@startimes.com.cn | |
| Address |
1124 Eldoret Close, Aminu Kano Crescent, Wuse 2, Abuja |
| State | Federal Capital Territory |
| Company Name | STARTIMES SMART ENERGY NIG LTD |
| Company Email | zhouzq@startimes.com.cn |
| Company Phone | 08037259175 |
| Tax Registration Number | 1258044 |
| Address |
11/12 FATAI ATERE WAY MUSHIN, LAGOS |
| State | Lagos |
| Name of the Village/Community | AMAC |
| State | Federal Capital Territory |
| Local Government Area | Abuja Municipal Area Council |
| Number of Inhabitants | 12 |
| GPS Coordinates | 8°59’20.51″N, 7°23’16.11″E |
| Site Address/Detail Description |
Close to National space research and Agency,Obasanjo space centre, Umaru musa ydar’adua express way, PMB 437, Lugbe, Abuja |
| Activities | Business Activity |
| Total Solar PV Installed (kWp) | 19.25 |
| Total Solar PV Energy Produce Per Day (kwh) | 86 |
| Total Storage Capacity (kwh) | 40 |
| Total Load/Energy Requirement (kWh) | 7 |
| Storage Technology/Manufacturer | Startimes |
| Type of Coupling (AC/DC) | DC |
| Generator Rated Power (kVA) | 12.5 |
| Year of Construction | 2014 |
| Fuel Type | Diesel |
| Generator Model/Manufacturer | FGWPEP67LGBK00334/FG WILSON |
| Operation | Manual |
| Date of Installation of Mini-Grid | August 10, 2024 |
| Date of Application | December 20, 2024 |
| Mini-Grid Owner (Full Name) | Solomon |
| Phone | 09131148680 |
| Manufacturer | Startimes |
| Model | CE-550HM |
| Technology | STARTIMES SOLAR |
| STC power (Wp) | 550 |
| Number of Cells | 35 |
| MPPT Current | 14.01 |
| MPPT Voltage | 49.8 |
| Module catalogue # | 2 |
| Number Series | Parallel | 7S, 4P |
| Total Power (Wp) | 15400 |
| Fuse (A) | 32 |
| Surge Protection Device | CHiNT |
| Converter Catalogue | 2 |
| Cable cross-section | 50 |
| Module catalogue # | 1 |
| Number Series | Parallel | 7S,1P |
| Total Power (Wp) | 3850 |
| Fuse (A) | 32 |
| Surge Protection Device | CHiNT |
| Converter Catalogue | 1 |
| Cable cross-section | 50 |
| Manufacturer | Startimes |
| Model | H100 |
| Technology | Startimes |
| Rated Power | 10kva |
| Rated Voltage | 48VDC |
| Rated Current | 229A |
| Manufacturer | Startimes |
| Model | H100 |
| Technology | Startimes |
| Rated Power | 10kva |
| Rated Voltage | 48VDC |
| Rated Current | 229A |
| Manufacturer | Startimes |
| Model | H50 |
| Technology | Startimes |
| Rated Power | 5kva |
| Rated Voltage | 48VDC |
| Rated Current | 63a |
| Manufacturer | Startimes |
| Model | 51.2V, 300AH |
| Technology | LITHIUM |
| Cell Voltage (V) | 3.2VDC |
| Battery Voltage | 51.2V |
| C10 Capacity | 15360WH |
| Charge Voltage | 54VDC |
| Module Catalogue # | 2 |
| Number Series | Parallel | 16S,1P |
| Total C10 capacity [kWh] | 15.36 |
| Fuse rating [A] | 125 |
| Date of cell production | April 16, 2024 |
| Date of installation | August 11, 2024 |
| Cable cross-section [mm²] | 35 |
| Module Catalogue # | 2 |
| Number Series | Parallel | 16S, 1P |
| Total C10 capacity [kWh] | 5.12 |
| Fuse rating [A] | 63 |
| Date of cell production | April 16, 2024 |
| Date of installation | August 11, 2024 |
| Cable cross-section [mm²] | 35 |
| PV Generator | Expected open circuit voltage [V] |
| String Number | 1 |
| Value | 320.1 |
| PV Generator | Expected open circuit voltage [V] |
| String Number | 2 |
| Value | 320.0 |
| PV Generator | Expected open circuit voltage [V] |
| String Number | 3 |
| Value | 320.2 |
| PV Generator | Expected open circuit voltage [V] |
| String Number | 4 |
| Value | 320.1 |
| PV Generator | Expected open circuit voltage [V] |
| String Number | 5 |
| Value | 320.0 |
| Inverter/Charge Controller | General visual inspection observations |
| String Number | 1 |
| Reference | Normal |
| Inverter/Charge Controller | General visual inspection observations |
| String Number | 2 |
| Reference | Normal |
| Inverter/Charge Controller | General visual inspection observations |
| String Number | 3 |
| Reference | Normal |
| Battery Storage | General visual inspection observations |
| String Number | 1 |
| Reference | Normal |
| General Safety/Security | General visual inspection observations |
| String Number | 1 |
| Reference | Normal |
| Official Letter of Request | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Request-Inspection-Letter-4.pdf |
| PV System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/PV-System-Install-150×150.jpg |
| Charge Controller or Grid-tie Inverter | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Inventor-System-150×150.jpg |
| Combiner Boxes | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Combiner-Box-1-150×150.jpg |
| Battery System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Battery-1-150×150.jpg |
| Earthing & Surge Protection System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Earthing-150×150.jpg |
| User ID | ZHENGQUAN ZHOU |