Admin Request for Inspection REA Solar Mini Grid
Application for | REA Solar Mini-Grid Project |
---|---|
REA Code | REA-NEP-MG |
REA LOT Number | 0372 |
REA-NEP-MG | PBG |
Blank | Benin |
Register as | Corporate |
NEMSA Certificate Number | REPC/CEIF/PR/00173 |
First Name | Stanley |
Last Name | Ike |
Position | Senior Project Manager |
Phone | 09032381477 |
stanleycike@nxtgrid.co | |
Address |
8b, John Obasi Kalu Close, Marwa, Lagos |
State | Lagos |
Company Name | NXT Grid Nigeria Ltd |
Company Email | stanley.ike@nxtgrid.co |
Company Phone | 09032381477 |
Tax Registration Number | 22623761-0001 |
Address |
John Obasi Kalu Close |
State | Lagos |
Name of the Village/Community | Evbuwa |
State | Edo |
Local Government Area | Orhionmwon |
Number of Inhabitants | 138 |
GPS Coordinates | 6.15861, 5.80583 |
Site Address/Detail Description |
Site is located in the middle of the community & is a popular landmark once in the community. |
Activities | Business Activity, Administrative Facility, Educational Facility, Residential |
Total Solar PV Installed (kWp) | 24.57 |
Total Solar PV Energy Produce Per Day (kwh) | 87 |
Total Storage Capacity (kwh) | 50 |
Total Load/Energy Requirement (kWh) | 5 |
Storage Technology/Manufacturer | BYD |
Type of Coupling (AC/DC) | DC |
Generator Rated Power (kVA) | 15 |
Year of Construction | 2023 |
Fuel Type | Diesel |
Generator Model/Manufacturer | Perkins |
Operation | Manual |
Date of Installation of Mini-Grid | January 16, 2023 |
Date of Application | March 18, 2024 |
Mini-Grid Owner (Full Name) | EtinPower Ltd |
Phone | 08033042184 |
yinka.omorogbe@gmail.com | |
Applicant | Stanley Ike |
Phone | 09032381477 |
stanley.ike@nxtgrid.co | |
Manufacturer | JA Solar |
Model | JAM72S20-455/MR |
Technology | Mono-Chrystalline |
STC power (Wp) | 455 |
Number of Cells | 144 |
MPPT Current | 85 |
MPPT Voltage | 250 |
Module catalogue # | JAM72S20 440-465/MR |
Number Series | Parallel | 5 | 2 |
Total Power (Wp) | 24.57 |
Fuse (A) | 15 |
Surge Protection Device | 40 kA |
Converter Catalogue | MPPT-250-60-up-to-250-100-EN |
Cable cross-section | 4 |
Manufacturer | Victron |
Model | SmartSolar Charge Controller MPPT 250/85-Tr |
Technology | MPPT |
Rated Power | 4.9 kW |
Rated Voltage | 250 |
Rated Current | 85 |
Manufacturer | BYD |
Model | BYD Battery-Box LV Flex |
Technology | Lithium-Ion Phosphate |
Cell Voltage (V) | 3.3 |
Battery Voltage | 51.2 |
C10 Capacity | 10A |
Charge Voltage | 48 |
Module Catalogue # | V1.2-6265116130b4d |
Number Series | Parallel | 1 | 10 |
Total C10 capacity [kWh] | 50 |
Fuse rating [A] | 100 |
Date of cell production | February 1, 2023 |
Date of installation | January 16, 2023 |
Cable cross-section [mm²] | 16 |
PV Generator | Measured power output [kW] |
String Number | MM6C |
Value | 3.1 |
Inverter/Charge Controller | All Inverters/Charge controller operating correctly? |
String Number | All |
Reference | Yes |
Battery Storage | Cell voltage |
String Number | 1 |
Reference | 3.3 |
General Safety/Security | Means of isolating the inverter been provided on the AC side? |
String Number | Other |
Reference | Isolation Switch Installed At Inverter AC side |
Official Letter of Request | https://nemsa.gov.ng/wp-content/uploads/formidable/67/EVBUWA-NEMSA-REQUEST-FOR-INSPECTION-LETTER_NXT-GRID_v02.pdf |
PV System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Screenshot-2024-03-26-2.33.15-PM-150×150.png |
Charge Controller or Grid-tie Inverter | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Screenshot-2024-03-26-2.34.51-PM-150×150.png |
Combiner Boxes | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Combiner-Box-Diagram.pdf |
Battery System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Screenshot-2024-03-26-2.36.58-PM-1-150×150.png |
Earthing & Surge Protection System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Earthing-System-Diagram.pdf |
User ID | Stanley Ike |