Admin Request for Inspection REA Solar Mini Grid
Application for | REA Solar Mini-Grid Project |
---|---|
REA Code | REA-NEP-MG |
REA LOT Number | 001 |
REA-NEP-MG | PBG |
Blank | Akure |
Register as | Corporate |
NEMSA Certificate Number | CC/CEIF/PR/00831 |
First Name | Wilson |
Last Name | Ige |
Position | Project Manager |
Phone | +2348101075333 |
wilson.ige@gommyr.com | |
Address |
Ibukun House, 1637 Adetokunbo Ademola Street, Victoria Island, Lagos, Nigeria. |
State | Lagos |
Company Name | Wavelength-Gommyr Power Networks |
Company Email | info@wavelengthips.com |
Company Phone | +2348093456999 |
Tax Registration Number | 223414784258 |
Address |
Ibukun House, 1637 Adetokunbo Ademola Street, Victoria Island, Lagos, Nigeria. |
State | Lagos |
Name of the Village/Community | Imula |
State | Ondo |
Local Government Area | Idanre |
Number of Inhabitants | 1800 |
GPS Coordinates | 6.897477, 5.201499 |
Site Address/Detail Description |
Imula is located at about 40 kilometers from Akure. It shares boundary with Olowoofeariwo and Omifunfun. |
Activities | Business Activity, Residential |
Total Solar PV Installed (kWp) | 123.12 |
Total Solar PV Energy Produce Per Day (kwh) | 430.92 |
Total Storage Capacity (kwh) | 243 |
Total Load/Energy Requirement (kWh) | 452.46 |
Storage Technology/Manufacturer | Lithium/AlphaESS |
Type of Coupling (AC/DC) | DC |
Generator Rated Power (kVA) | 100 |
Year of Construction | 2019 |
Fuel Type | Diesel |
Generator Model/Manufacturer | FG WILSON |
Operation | Automatic |
Date of Installation of Mini-Grid | July 29, 2023 |
Date of Application | August 18, 2023 |
Manufacturer | Jinko Solar |
Model | JKM380N-6TL3-V |
Technology | N-Type Mono-crystalline |
STC power (Wp) | 380 |
Number of Cells | 120 |
MPPT Current | 10.93 |
MPPT Voltage | 34.77 |
Module catalogue # | A-1 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | A-1 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | A-2 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | A-2 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | A-3 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | A-3 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | B-1 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | B-1 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | B-2 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | B-2 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | B-3 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | B-3 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | C-1 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | C-1 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | C-2 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | C-2 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | C-3 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | C-3 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | D-1 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | D-1 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | D-2 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | D-2 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | D-3 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | D-3 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | E-1 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | E-1 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | E-2 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | E-2 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | E-3 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | E-3 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | F-1 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | F-1 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | F-2 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | F-2 |
Cable cross-section | 6 sq. mm. |
Module catalogue # | F-3 |
Number Series | Parallel | 18 | 1 |
Total Power (Wp) | 6,840 |
Fuse (A) | 15 |
Surge Protection Device | Class II |
Converter Catalogue | F-3 |
Cable cross-section | 6 sq. mm. |
Manufacturer | Sinexcel |
Model | Storion T100 |
Technology | MPPT |
Rated Power | 100 kW |
Rated Voltage | 400 V |
Rated Current | 144 A |
Manufacturer | AlphaESS |
Model | M38210-S |
Technology | LiFeP04 |
Cell Voltage (V) | 38.4 |
Battery Voltage | 395 V |
C10 Capacity | 10.5 A |
Charge Voltage | 51.2 V |
Module Catalogue # | Cluster 1 |
Number Series | Parallel | 10 | 1 |
Total C10 capacity [kWh] | 24.3 |
Fuse rating [A] | 250A |
Date of cell production | January 11, 2022 |
Date of installation | July 22, 2023 |
Cable cross-section [mm²] | 70 sq. mm. |
PV Generator | Expected open circuit voltage [V] |
String Number | Each of 18 Strings |
Value | 726 V |
PV Generator | Measured open circuit voltage [V] |
String Number | Each of 18 Strings |
Value | 700 V |
PV Generator | Expected power output [kW] |
String Number | All 18 strings |
Value | 120 kWp |
PV Generator | Measured power output [kW] |
String Number | All 18 strings |
Value | 115.12 kWp |
PV Generator | General visual inspection observations |
String Number | Every Equipment |
Value | Ok |
PV Generator | Surge Protective Devices functional (indicator at device)? |
String Number | All SPDs |
Value | All indicators are in good state |
PV Generator | Overcurrent protection operational (correct fuse rating)? |
String Number | All MCBs and MCCBs |
Value | All MCBs and MCCBs are rated accordingly |
PV Generator | String cables fixed and cables without damages |
String Number | All connecting cables |
Value | Every cable was propoerly routed and installed properly |
PV Generator | Connectors properly connected under no mechanical strain |
String Number | All connectors |
Value | Every connector was installed without tensoining |
Inverter/Charge Controller | General visual inspection observations |
String Number | Sinexcel PCS |
Reference | The inverter operates smoothly, all the input and output values are consistent. |
Inverter/Charge Controller | Inverter protection settings programmed to local requirements? |
String Number | Sinexcel PCS |
Reference | Settings were configured and localized according to the manufacturer guide |
Inverter/Charge Controller | Means of isolating the inverter been provided on the AC side? |
String Number | 1 |
Reference | Yes |
Inverter/Charge Controller | Isolating and switching devices been connected such that PC installation is wired to the “load” side and the public supply to the “source” side? |
String Number | 1 |
Reference | Yes |
Inverter/Charge Controller | All Inverters/Charge controller operating correctly? |
String Number | 1 |
Reference | Yes |
Inverter/Charge Controller | Inverter/charge controller protection settings and installer details displayed on site? |
String Number | 1 |
Reference | Yes |
Battery Storage | General visual inspection observations |
String Number | AlphaESS |
Reference | BESS installed and kept at low operating temperature |
Battery Storage | Wiring properly done without visual deficits |
String Number | 1 |
Reference | Yes |
Battery Storage | Tightening torque of all screws to connectors to the batteries and in between the cells of the batteries is according to the equipment manufacturer’s recommendations |
String Number | 1 |
Reference | Yes |
Battery Storage | Battery inverter or charge controller parameters are properly set (correct system configuration, date and time, control of the load shedding relays, reading of external temperature sensor verified, …) |
String Number | 1 |
Reference | Yes |
Battery Storage | State of charge (If applicable state of health) |
String Number | 1 |
Reference | 100% |
Battery Storage | Safety measures for the respective types of batteries applied |
String Number | 1 |
Reference | Safety measure is in place |
Battery Storage | Deep discharge protection, over-charge protection and temperature monitoring installed and functional |
String Number | 1 |
Reference | All these parameters have been set, an Air Conditioner is installed to regulate the room temperature |
Battery Storage | Cell voltage |
String Number | Each of the 30 units of Cell |
Reference | 39.5 |
General Safety/Security | General visual inspection observations |
String Number | 1 |
Reference | The site was built with safety consideration |
Official Letter of Request | https://nemsa.gov.ng/wp-content/uploads/formidable/67/NEMSA-Inspection-Letter.pdf |
PV System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/JKM360-380N-6TL3-V-F2.1-EN-1.pdf |
Charge Controller or Grid-tie Inverter | https://nemsa.gov.ng/wp-content/uploads/formidable/67/BD_NGA_REA_Battery-Inverter-datasheet_1v00_04Apr2022-1.pdf |
Combiner Boxes | https://nemsa.gov.ng/wp-content/uploads/formidable/67/helioscope_shading_11652206_summary_Imula_123.12kWp.pdf |
Battery System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/BD_NGA_REA_Battery-Datasheet_1v00_04Apr2022-2.pdf |
Earthing & Surge Protection System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Indelec-prevectron-3-TS25.pdf |
User ID | Wilson Ige |