Admin Request for Inspection REA Solar Mini Grid
Application for | REA Solar Mini-Grid Project |
---|---|
REA Code | REA-NEP-MG |
REA LOT Number | rea-nep/mg/pbg/89/20 |
REA-NEP-MG | PBG |
Blank | Uyo |
Register as | Corporate |
NEMSA Certificate Number | CC/CEIF/PR/03490 |
First Name | Chris |
Last Name | Ebiware |
Position | Country Manager |
Phone | 08039253885 |
cebiware@renewvia.com | |
Address |
11 Chikwele Street, Unity Estate, Eliogboilo, Port Harcourt, Rivers State, Nigeria. |
State | Rivers |
Company Name | Renewvia Soalr Nigeria Limited |
Company Email | info@renewvia.com |
Company Phone | 08039253885 |
Tax Registration Number | 19844167-0001 |
Address |
11 Chikwele Street, Unity Estate, Eliogboilo, Port Harcourt, Rivers State, Nigeria. |
State | Rivers |
Name of the Village/Community | Emereoke |
State | Akwa Ibom |
Local Government Area | Eastern Obolo |
Number of Inhabitants | 2600 |
GPS Coordinates | 4.5025801, 7.67457 |
Activities | Business Activity, Administrative Facility, Educational Facility, Health Care Facility, Residential |
Total Solar PV Installed (kWp) | 28.08 |
Total Solar PV Energy Produce Per Day (kwh) | 85.54 |
Total Storage Capacity (kwh) | 66.6 |
Total Load/Energy Requirement (kWh) | 86.42 |
Storage Technology/Manufacturer | Lithium Iron Phosphate |
Type of Coupling (AC/DC) | DC |
Generator Rated Power (kVA) | 62.5 |
Year of Construction | 2021 |
Fuel Type | Diesel |
Generator Model/Manufacturer | Electromak |
Operation | 180 |
Date of Installation of Mini-Grid | April 1, 2022 |
Date of Application | September 25, 2022 |
Mini-Grid Owner (Full Name) | Chris Ebiware |
Phone | 08039253885 |
cebiware@renewvia.com | |
Manufacturer | Jinko Solar |
Model | JKM390M-72 |
Technology | Monocrystalline |
STC power (Wp) | 390 |
Number of Cells | 72 |
MPPT Current | 9.49 |
MPPT Voltage | 41.1 |
Module catalogue # | 1 |
Number Series | Parallel | 4|3 |
Total Power (Wp) | 4680 |
Fuse (A) | 50 |
Surge Protection Device | 40KA |
Converter Catalogue | 1 |
Cable cross-section | 10MMSQ |
Module catalogue # | 2 |
Number Series | Parallel | 4|3 |
Total Power (Wp) | 4680 |
Fuse (A) | 50 |
Surge Protection Device | 40KA |
Converter Catalogue | 2 |
Cable cross-section | 10MMSQ |
Module catalogue # | 3 |
Number Series | Parallel | 4|3 |
Total Power (Wp) | 4680 |
Fuse (A) | 50 |
Surge Protection Device | 40KA |
Converter Catalogue | 3 |
Cable cross-section | 10MMSQ |
Module catalogue # | 4 |
Number Series | Parallel | 4|3 |
Total Power (Wp) | 4680 |
Fuse (A) | 50 |
Surge Protection Device | 40KA |
Converter Catalogue | 4 |
Cable cross-section | 10MMSQ |
Module catalogue # | 5 |
Number Series | Parallel | 4|3 |
Total Power (Wp) | 4680 |
Fuse (A) | 50 |
Surge Protection Device | 40KA |
Converter Catalogue | 5 |
Cable cross-section | 10MMSQ |
Module catalogue # | 6 |
Number Series | Parallel | 4|3 |
Total Power (Wp) | 4680 |
Fuse (A) | 50 |
Surge Protection Device | 40KA |
Converter Catalogue | 6 |
Cable cross-section | 10MMSQ |
Manufacturer | Victron |
Model | Smart Solar 250/85 |
Technology | MPPT |
Rated Power | 4900 |
Rated Voltage | 250 |
Rated Current | 85 |
Manufacturer | Victron |
Model | Smart Solar 250/85 |
Technology | MPPT |
Rated Power | 4900 |
Rated Voltage | 250 |
Rated Current | 85 |
Manufacturer | Victron |
Model | Smart Solar 250/85 |
Technology | MPPT |
Rated Power | 4900 |
Rated Voltage | 250 |
Rated Current | 85 |
Manufacturer | Victron |
Model | Smart Solar 250/85 |
Technology | MPPT |
Rated Power | 4900 |
Rated Voltage | 250 |
Rated Current | 85 |
Manufacturer | Victron |
Model | Smart Solar 250/85 |
Technology | MPPT |
Rated Power | 4900 |
Rated Voltage | 250 |
Rated Current | 85 |
Manufacturer | Victron |
Model | Smart Solar 250/85 |
Technology | MPPT |
Rated Power | 4900 |
Rated Voltage | 250 |
Rated Current | 85 |
Manufacturer | Solar MD |
Model | SS202-01 |
Technology | Lithium Iron Phosphate |
Cell Voltage (V) | 3.2 |
Battery Voltage | 51.2 |
C10 Capacity | 245 |
Charge Voltage | 53.4 |
PV Generator | Expected open circuit voltage [V] |
String Number | 6 |
Value | 194.4 |
PV Generator | Measured open circuit voltage [V] |
String Number | 6 |
Value | 186.6 |
PV Generator | Expected load circuit voltage [V] |
String Number | 6 |
Value | 158.56 |
PV Generator | Measured load circuit voltage [V] |
String Number | 6 |
Value | 148.25 |
PV Generator | Expected short circuit current [A] |
String Number | 6 |
Value | 31.38 |
PV Generator | Measured ambient temperature [°C] |
String Number | 6 |
Value | 37 |
PV Generator | Alternatively, estimated insulation (cloudy, sunny, mist, …) |
String Number | 6 |
Value | sunny |
PV Generator | Expected power output [kW] |
String Number | 6 |
Value | 4.68 |
PV Generator | Measured insulation resistance [Mega Ohm] |
String Number | 6 |
Value | 1000 |
PV Generator | Measured earth resistance of support structure [Ohm] |
String Number | 6 |
Value | 7.2 |
PV Generator | General visual inspection observations |
String Number | 6 |
Value | OK |
PV Generator | Surge Protective Devices functional (indicator at device)? |
String Number | 6 |
Value | OK |
PV Generator | Overcurrent protection operational (correct fuse rating)? |
String Number | 6 |
Value | YES |
PV Generator | String cables fixed and cables without damages |
String Number | 6 |
Value | YES |
PV Generator | Connectors properly connected under no mechanical strain |
String Number | 6 |
Value | YES |
Inverter/Charge Controller | General visual inspection observations |
String Number | 6 |
Reference | OK |
Inverter/Charge Controller | Inverter protection settings programmed to local requirements? |
String Number | 6 |
Reference | YES |
Inverter/Charge Controller | Means of isolating the inverter been provided on the AC side? |
String Number | 6 |
Reference | YES |
Inverter/Charge Controller | Isolating and switching devices been connected such that PC installation is wired to the “load” side and the public supply to the “source” side? |
String Number | 6 |
Reference | YES |
Inverter/Charge Controller | All Inverters/Charge controller operating correctly? |
String Number | 6 |
Reference | YES |
Battery Storage | General visual inspection observations |
String Number | 1 |
Reference | OK |
Battery Storage | Wiring properly done without visual deficits |
String Number | 1 |
Reference | YES |
Battery Storage | Tightening torque of all screws to connectors to the batteries and in between the cells of the batteries is according to the equipment manufacturer’s recommendations |
String Number | 1 |
Reference | YES |
Battery Storage | Battery inverter or charge controller parameters are properly set (correct system configuration, date and time, control of the load shedding relays, reading of external temperature sensor verified, …) |
String Number | 1 |
Reference | YES |
Battery Storage | State of charge (If applicable state of health) |
String Number | 1 |
Reference | 100% |
Battery Storage | Deep discharge protection, over-charge protection and temperature monitoring installed and functional |
String Number | 1 |
Reference | YES |
General Safety/Security | General visual inspection observations |
Official Letter of Request | https://nemsa.gov.ng/wp-content/uploads/formidable/67/220422-Request-for-NEMSA-Site-Inspection-at-Emereoke-1-150×150.jpg |
PV System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/Emereoke-Electrical-Wiring-Diagram-Final_SLD.pdf |
Charge Controller or Grid-tie Inverter | https://nemsa.gov.ng/wp-content/uploads/formidable/67/EMEREOKE-NEMSA-APPLICATION-03-150×150.jpg |
Combiner Boxes | https://nemsa.gov.ng/wp-content/uploads/formidable/67/EMEREOKE-NEMSA-APPLICATION-03-1-150×150.jpg |
Battery System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/EMEREOKE-NEMSA-APPLICATION-07-150×150.jpg |
Earthing & Surge Protection System | https://nemsa.gov.ng/wp-content/uploads/formidable/67/EMEREOKE-NEMSA-APPLICATION-16-150×150.jpg |